isoflurane vaporizer suppliers

The NET anesthesia machine are used by anesthesiologists, nurse anesthetists to support the administration of anesthesia.It is designed to provide an accurate and continuous supply of medical gases (such as oxygen and nitrous oxide), which are mixed with an accurate concentration of anaesthetic vapour (such as isoflurane), and then delivered to the patient at a safe pressure and flow.AN300 - Anesthesia machine with LED Screen With LED screen.Mounted on 4 castors.2 front castors with brakes.With 2 big drawers .Handle for easy maneuvering Epoxy painted high quality mild steel frame.Equipped with Anesthesia Vaporizer.Agent type: Isoflurane/ Enflurane/ Halothane (Select anyone) Classical CO2 circle absorber with 1 canister With necessary monitoring and alarm function, to ensure the operational safety.Ask for Price Feature : Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi-open, Semi-closed or closed system Anesthetic vaporizer: One vaporizer Anesthesia Ventilator Specification : Display : High Power LED display Ventilation mode : IPPV and Manual mode Tidal Volume : 50 ~ 1600ml Breath frequency : 1 ~ 90BPM I: E ratio: 4: 1 ~ 1: 6 Monitor parameter Tidal volume, Breath frequency, MV, airway pressure.

Alarm MV high alarm, MV low alarm TV high alarm, TV low alarm Main Unit : Circle absorber : Compact circle absorber Bellow : 50 ~ 1600ml Oxygen Flush : 25L/min ~ 75L/min Flow meter : O2, N2O two-tube flow meter O2 tube: 0L/min ~ 10L/min N2O tube: 0L/min ~ 10L/min O2 and N2O linkage device Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% ) Gas source pressure : O2: 0.25 ~ 0.65Mpa N2O: 0.25~ 0.65Mpa Gauge : 2 units, one N2O, one O2 Item Code : Type AN305 Same as AN300 but with Classical CO2 circle absorber with 2 canisters Fresh gas outlet is in front of frame for the user to easily connect Jackson-Rees circuit.
vape shop inverness scotlandGeneral gas switch is in front of frame Flow meter : O2, two-tube flow meter O2 tube: 0L/min ~ 10L/min ~ 10L/min Gas source pressure : O2: 0.25 ~ 0.65Mpa Gauge : 1 unit, one O2 AN310 - Anesthesia machine with 5.5" SNT screen With 5.5" SNT screen.
personal vaporizer bogor

With 2 big drawers.Handle for easy maneuvering.Epoxy painted high quality mild steel frame.Equipped with High precise Anesthesia Vaporizer (with temperature, flow and pressure compensation function).The agent output is continuous, stable & precise.The agent type: Isoflurane/ Enflurane/ Halothane/ Sevoflurane (Select any one) Anesthesia ventilator with IPPV and SIMV mode.The ventilator can display P-t and V-t wave-form at the same time.
topoo vaporizer not workingNecessary monitoring and alarm function to ensure operational safety.
vicks vaporizer v150sgnClassical CO2 circle absorber with 2 canisters for low resistance and minimum gas leakage.
snoop dogg g pen vape reviewOptional : O2, N2O Yoke device.
dry herb vaporizer pen wiki

When main gas supply fails, the backup gas supply starts.Ask for Price Feature : Patient type : Adult, Pediatric Driven mode : Pneumatically driven electronically controlled Mode : Semi-open, Semi-closed or Closed system Anesthetic vaporizer : One vaporizer Power supply : 220V+/-10%, 50Hz+/-1Hz Power consumption : Not more than 50W Internal battery : DC12V (over 4 working hours) Anesthesia Ventilator Specification : Respiration mode : IPPV, SIMV, SIGH, MANUAL Waveform : P-t, V-t Tidal volume : 50ml~1600ml Respiratory frequency : 1~65 BPM / I: E ratio: 8: 1~1: 8 Alarm parameters : High pressure alarm, Low pressure alarm, O2 source failure alarm High pressure alarm limit: 20~60CMH2O / Low pressure alarm limit: 0~20CMH2O Monitor parameters : Tidal volume, MV, Ppeak, PEEP, respiratory frequency, I: E ratio Safety valve pressure limit : 6 Kpa Main Unit : Circle absorber : Compact Circle absorber Bellow : 0 ~ 1600ml Flow meter : O2, N2O four-tube flow meter O2 tube: 0L/min~1L/min~10L/min N2O tube: 0L/min~1L/min~10L/min O2 and N2O linkage device Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% ) Oxygen Flush : 25L/min ~ 75L/min Gas source pressure : O2: 0.25 ~ 0.65Mpa N2O: 0.25~ 0.65Mpa Gauge : 2 units, one N2O, one O2 AN315 - Anesthesia Machines With 5.5" SNT screen.
vaporizer katowice

With 2 big drawers Handle for easy maneuvering.Aluminium alloy rail frame.With durable and non-corrosive stainless steel platform.Equipped with high precise Anesthesia Vaporizer (with temperature, flow and pressure compensation function).The agent type: Isoflurane OR Enflurane.With independent Anesthesia Ventilator, the ventilator frame is moulded and height can be adjusted.Fresh gas outlet is in front of frame for the user to easily connect Jackson-Rees circuit.
docteur vaporizerOptional : O2, N2O Yoke device.
g5 vaporizer pen instructionsWhen main gas supply is fails, the backup gas supply starts.Ask for Price Feature : Patient type : Adult, Pediatric Driven mode : Pneumatically driven electronically controlled Mode : Semi-open, Semi-closed or closed system Anesthetic vaporizer : One high precise Vaporizer (Optional : with Two Vaporizers) Power supply : 220V±10%, 50Hz±1Hz Power consumption : <50W Internal battery : DC12V (over 2 hours) Anesthesia Ventilator Specification : Respiration mode : IPPV, SIMV, SIGH, MANUAL Waveform : P-t, V-t Tidal Volume : 50 ~ 1600ml Respiratory frequency : 1 to 65 BPM I: E ratio: 8: 1~1: 8 Alarm parameters: High pressure alarm Low pressure alarm O2 source failure alarm AC power failure alarm High pressure alarm limit : 20~60CMH2O Low pressure alarm limit : 0~20CMH2O Monitor parameters : Tidal volume, MV, Ppeak, PEEP, respiratory frequency, I: E ratio, Airway pressure Safety valve pressure limit : 6 Kpa Good air tightness, high reliability and minor respiration impedance Main Unit : Circle absorber : Compact circle absorber Flow meter : O2, N2O four-tube flow meter O2 tube: 0L/min~1L/min~10L/min N2O tube: 0L/min~1L/min~10L/min O2 and N2O Linkage Device: Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% ) Oxygen Flush : 25L/min ~ 75L/min Gas source pressure : O2: 0.25 ~ 0.65Mpa N2O: 0.25~ 0.65Mpa Gauge : Two gauges, N2O, O2 AN320 - Anesthesia Machine with 10.4" TFT screen With 10.4 TFT color screen.

Equipped with Two high precise Anesthesia Vaporizer (with temperature, flow and pressure compensation function).The agent type: Isoflurane OR Enflurane OR Halothane OR Sevoflurane.(Any Two) Classical CO2 circle absorber with 2 canisters for low resistance and minimum gas leakage.Optional: O2, N2O Yoke device.When main gas supply is fails, the Backup gas supply starts.Ask for Price Features : Application : Adult, Pediatric Driven mode : Pneumatically driven electronically controlled Mode : Semi-open, Semi-closed or closed system Anesthetic vaporizer : Two high precise vaporizers Power supply : 220V±10%, 50Hz ±1Hz 110V±10%, 60Hz ±1Hz Internal battery : DC12V (over 4 working hours) Anesthesia Ventilator Specification : Waveform : P-t, F-t Tidal Volume : 50ml ~ 1600ml Respiratory frequency : 1 ~ 65 BPM I: E ratio: 4: 1~1: 4 Inspiration pause : 0~55%Ti Inspiration Pressure : 1~60cmH2O Trigger Pressure : -20~20cmH2O Monitor parameters : O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, I:E ratio, Pmean, etc.. Pressure alarm setting : High pressure alarm set 1~60cmH2O Low pressure alarm set 0~20cmH2O O2 concentration alarm setting: high 21~99% low 21~50% MV alarm setting : MV high alarm set 10~99L/min MV low alarm set 0~40L/min Main Unit : Circle absorber : Compact circle absorber Flow meter : O2, N2O four-tube flow meter O2 tube: 0L/min~1L/min~10L/min N2O tube: 0L/min~1L/min~10L/min O2 and N2O linkage device, keep oxygen concentration over 25% Oxygen Flush : 25L/min ~ 75L/min Gas source pressure : O2: 0.25MPa ~ 0.65MPa N2O: 0.25MPa ~ 0.65MPa Gauge : 4 units, 2×N2O, 2×O2 AN325 - Anesthesia machine integrated for Pediatric and Adult With 10.4 TFT color screen Mounted on 4 castors.

With 1 safety lock and 3 big drawers.The agent type: Isoflurane/ Enflurane/ Halothane/ Sevoflurane (Select any two).With Volume & pressure ventilation modes.With upgraded with functions, eg, CO2 Monitor, Multi-parameter monitor, Anesthesia depth monitor, etc.Working interfaces for adult and pediatric are separated; the doctor can choose interface according to patient type.Optional: O2, N22 Yoke device.When main gas supply is fails, The backup gas supply starts.Ask for Price Features : Application : Adult, Pediatric Driven mode : Pneumatically driven electronically controlled Mode : Semi-open, Semi-closed or closed system Anesthetic vaporizer : Two high precise vaporizers, Isoflurane, Enflurane, Halothane, Sevoflurane.Power supply : 220V±10%, 50Hz ±1Hz Internal battery : DC12V (over 4 working hours) Fresh gas outlet is in front of frame Anesthesia Ventilator : Respiration mode : IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO Waveform : P-t, F-t, V-t, F-v, V-p Tidal Volume : 20~1600ml Respiratory frequency : 1 ~ 65 BPM I: E ratio: 4: 1~1: 4 Inspiration pause : 0~55%Ti Inspiration Pressure : 1~60cmH2O Trigger Pressure : -20~20cmH2O Monitoring parameters : O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I: E ratio, Pmean, etc. Alarm parameters : High pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc. Pressure alarm setting : High pressure alarm set 1~60cmH2O Low pressure alarm set 0~20cmH2O O2 concentration alarm setting: high 21~99% low 21~50% MV alarm setting : MV high alarm set 10~99L/min MV low alarm set 0~40L/min Main Unit : Circle absorber : Compact circle absorber Flow meter : Five~tube flow meter O2 tube: 0L/min~1L/min~10L/min.