tomco co2 vaporizer

CO2 Vaporizers Using a temperature-controlled heating source, our CO2 Vaporizers systems are designed to vaporize liquid CO2 to a gas and trim heat the CO2 gas to the required temperature.These units are available in electric, steam or water configurations.Select a Vaporizer... - Steam Heated Water Bath Vaporizers - Vapor Heaters - Water Bath Vaporizers - Direct to Process VaporizersPressure-build Vaporizers Pressure-build vaporizers from TOMCO2 Systems employ a temperature- and pressure-controlled immersion-heating element to maintain CO2 pressure in storage units during CO2 withdraw.Electrical enclosure is a NEMA 3R standard for outdoor use 1" (2.54 cm) Carbon Dioxide blow down valve Dual high temperature shutdown switches 450 psig relief valve Variable pressure control Capacities from 9 KW to 80 KW units available (Other sizes available upon request) 230/460 Volt, 60 Hz., 3 Phase operation (Other voltages available upon request) Give us a call: Model Capacity Wattage Dimensions (LxWxH) Weight M-259 245 lbs/hr @ 230V / 325 lbs/hr @ 460V 9,000 / 12,000 60" x 19" x 50" 231 lbs 111 kgs/hr @ 230V / 147 kgs/hr @ 460V 9,000 / 12,000 152.4 cm x 48.3 cm x 127 cm 105 kgs M-418 490 lbs/hr @ 230V / 650 lbs/hr @ 460V 18,000 / 24,000 60" x 19" x 50" 233 lbs 222 kgs/hr @ 230V / 295 kgs/hr @ 460V 18,000 / 24,000 152.4 cm x 48.3 cm x 127 cm 106 kgs M-628 760 lbs/hr @ 230V/460V 28,000 55" x 21" x 57" 386 lbs 345 kgs/hr @ 230V/460V 28,000 139.7 cm x 53.3 cm x 144.8 cm 175 kgs M-1256 1525 lbs/hr @ 230V/460V 56,000 101" x 21" x 57" 698 lbs 692 kgs/hr @ 230V/460V 56,000 256.5 cm x 53.3 cm x 144.8 cm 317 kgs M-1280 2185 lbs/hr @ 230V/460V 80,000 132" x 22" x 57" 800 lbs 991 kgs/hr @ 230V/460V 80,000 334.9 cm x 56.5 cm x 144.8 cm 363 kgs

Direct to Process Vaporizers If steam or water are unavailable, highly energy efficient Direct to Process Vaporizers will meet all your vapor needs.Electrical enclosure is a NEMA 3R equivalent standard for outdoor use Replaceable heater platen Pilot light indicator for control power & heater cycle Low discharge temperature safety cut off Circuit breaker load protection Capacities from 15 KW to 120 KW (Other sizes available upon request) Standard Electrical Requirements: 240/480 volt, 60Hz, 3 phase (others available upon request) Stainless steel and floor stand available upon request.Give us a call: Model Capacity Wattage Dimensions Weight DTP-15 350 lbs/hr 15,000 22" x 23" x 37" 265 lbs 159 kg/hr 15,000 55.9 cm x 58.4 cm x 94 cm 120 kg DTP-30 695 lbs/hr 30,000 22" x 23" x 37" 305 lbs 315 kg/hr 30,000 55.9 cm x 58.4 cm x 94 cm 139 kg DTP-45 1045 lbs/hr 45,000 22" x 23" x 37" 345 lbs 474 kg/hr 45,000 55.9 cm x 58.4 cm x 94 cm 157 kg DTP-60 1395 lbs/hr 60,000 22" x 23" x 37" 375 lbs 633 kg/hr 60,000 55.9 cm x 58.4 xm x 94 cm 170 kg DTP-75 1745 lbs/hr.

75,000 22" x 23" x 37" 385 lbs 792 kg/hr.75,000 55.9 cm x 102 cm x 94 cm 175 kg DTP-90 2,095 lbs/hr 90,000 26” x 45” x 43” 395 lbs 950 kg/hr 90,000 66 cm x 114.3 cm x 109.2 cm 179 kg DTP-120 2,795 lbs/hr 120,000 27” x 48” x 43” 430 lbs 1,268 kg/hr 120,000 68.7 cm x 121.9 cm x 109.2 cm 195 kg DTP-150 3,495 lbs/hr 150,000 27" x 73" 43" 465 lbs 1,585 kg/hr 150,000 68.7 cm x 185.4 cm x 109.2 cm 211 kg Note: The above DTP capacities are based on 70° discharge CO2 gas temperatures with a minimum CO2 supply pressure of 285 psig.
vaporizer bazos---AfghanistanAlbaniaAlgeriaAmerican SamoaAndorraAngolaAnguillaAntarcticaAntigua and BarbudaArgentinaArmeniaArctic OceanArubaAshmore and Cartier IslandsAtlantic OceanAustraliaAustriaAzerbaijanBahamasBahrainBaker IslandBangladeshBarbadosBassas da IndiaBelarusBelgiumBelizeBeninBermudaBhutanBoliviaBosnia and HerzegovinaBotswanaBouvet IslandBrazilBritish Virgin IslandsBruneiBulgariaBurkina FasoBurundiCambodiaCameroonCanadaCape VerdeCayman IslandsCentral African RepublicChadChileChinaChristmas IslandClipperton IslandCocos IslandsColombiaComorosCook IslandsCoral Sea IslandsCosta RicaCote d'IvoireCroatiaCubaCyprusCzech RepublicDenmarkDemocratic Republic of the CongoDjiboutiDominicaDominican RepublicEast TimorEcuadorEgyptEl SalvadorEquatorial GuineaEritreaEstoniaEthiopiaEuropa IslandFalkland Islands (Islas Malvinas)Faroe IslandsFijiFinlandFranceFrench GuianaFrench PolynesiaFrench Southern and Antarctic LandsGabonGambiaGaza StripGeorgiaGermanyGhanaGibraltarGlorioso IslandsGreeceGreenlandGrenadaGuadeloupeGuamGuatemalaGuernseyGuineaGuinea-BissauGuyanaHaitiHeard Island and McDonald IslandsHondurasHong KongHowland IslandHungaryIcelandIndiaIndian OceanIndonesiaIranIraqIrelandIsle of ManIsraelItalyJamaicaJan MayenJapanJarvis IslandJerseyJohnston AtollJordanJuan de Nova IslandKazakhstanKenyaKingman ReefKiribatiKerguelen ArchipelagoKosovoKuwaitKyrgyzstanLaosLatviaLebanonLesothoLiberiaLibyaLiechtensteinLithuaniaLuxembourgMacauMacedoniaMadagascarMalawiMalaysiaMaldivesMaliMaltaMarshall IslandsMartiniqueMauritaniaMauritiusMayotteMexicoMicronesiaMidway IslandsMoldovaMonacoMongoliaMontenegroMontserratMoroccoMozambiqueMyanmarNamibiaNauruNavassa IslandNepalNetherlandsNetherlands AntillesNew CaledoniaNew ZealandNicaraguaNigerNigeriaNiueNorfolk IslandNorth KoreaNorth SeaNorthern Mariana IslandsNorwayOmanPacific OceanPakistanPalauPalmyra AtollPanamaPapua New GuineaParacel IslandsParaguayPeruPhilippinesPitcairn IslandsPolandPortugalPuerto RicoQatarReunionRepublic of the CongoRomaniaRussiaRwandaSaint HelenaSaint Kitts and NevisSaint LuciaSaint Pierre and MiquelonSaint Vincent and the GrenadinesSamoaSan MarinoSao Tome and PrincipeSaudi ArabiaSenegalSerbiaSeychellesSierra LeoneSingaporeSlovakiaSloveniaSolomon IslandsSomaliaSouth AfricaSouth Georgia and the South Sandwich IslandsSouth KoreaSpainSpratly IslandsSri LankaSudanSurinameSvalbardSwazilandSwedenSwitzerlandSyriaTaiwanTajikistanTanzaniaThailandTogoTokelauTongaTrinidad and TobagoTromelin IslandTunisiaTurkeyTurkmenistanTurks and Caicos IslandsTuvaluUgandaUkraineUnited Arab EmiratesUnited KingdomUSAUruguayUzbekistanVanuatuVenezuelaViet NamVirgin IslandsWake IslandWallis and FutunaWest BankWestern SaharaYemenYugoslaviaZambiaZimbabwe CO2 Application Equipment TOMCO2 Systems’ vaporizers are most effective and reliable in transforming your liquid CO2 into CO2 vapor.
flavorizer bars for genesis e 310